Extend eaves 1’ and box in soffits.
Install EPS flute, fill in insulation in the low flutes of the existing metal roofing.
Install one layer of recovery board underlayment to provide a smooth surface to accept the new membrane.
Mechanically fasten the Duro-Last single-ply membrane in accordance with Duro-Last requirements.
Flash all parapet and adjacent building walls in accordance with Duro-Last fastening requirements.
At all perimeter edges bring the membrane over the edge fastening 6” O.C.
Install new Duro-Last metal edging on all perimeter edges.
Flash all roof penetrations in accordance with Duro-Last requirements.